XP 1100 SINE WAVE INVERTER 12-108 VDC INPUT 100, 120 or 230 VAC OUTPUT @ 1100W 50, 60, or 400Hz available Designed to operate in mobile & extreme rugged environments UL Listed to 1950 for Telecom applications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model No. |
0/P Designation |
Output Voltages |
I/P Designation |
Input Voltages |
Freq. Designation |
Frequencies |
Option Designation |
Options |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
XP 1100 |
0 |
100 VAC |
1 |
12 VDC |
5 |
50 Hz |
07 |
Conformal Coat |
|
|
|
|
1 |
120 VAC |
2 |
24 VDC |
6 |
60 Hz |
04 |
Circuit Board w / heat sink** |
|
|
|
|
3 |
230 VAC |
B |
32 VDC |
4 |
400 Hz |
|
|
|
|
|
|
|
|
4 |
48 VDC |
|
|
|
|
|
|
|
|
|
|
E |
66 VDC |
|
|
|
|
|
|
|
|
|
|
I |
108 VDC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
** OEM ONLY |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
To create part number pick designation. Example below is XP1100, 100 VAC output, 24 VDC input, 60 Hz, Conformal Coated |
|
||||||||
|
|
XPK |
0 |
|
2 |
|
6 |
|
07 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
XPK-___-___-___-1-____ |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
OUTPUT POWER |
|
|
|||||||
|
|
Continuous Power |
Surge Power |
No Load Power |
Output Voltage |
Output Current |
Weight Lbs |
Mechanical |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1100W |
2200W |
20W* |
100 +/-6% |
11 |
10 |
3.57" X 7.69" X 15.05" |
|
|
|
|
|
1100W |
2200W |
20W* |
117 +/-6% |
9.5 |
10 |
3.57" X 7.69" X 15.05" |
|
|
|
|
|
1100W |
2200W |
20W* |
230 +/-6% |
4.8 |
10 |
3.57" X 7.69" X 15.05" |
|
|
|
|
|
* 10W w/ X2 option |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INPUT POWER |
|
PROTECTION CIRCUITRY |
|
||||||
|
|
Input Voltage |
Minimum¹ Voltage (Typical) |
System Voltage (Typical) |
Maximum¹ Voltage (Typical) |
Typical Efficiency @ Full Power |
Peak Efficiency @ 1/3 power |
|
*OVP |
Shut off at maximum input voltage, per input conditions. Automatic reset upon fault correction |
|
|
|
|
|
|
|
|
|
|
*Under Voltage |
Shutoff at minimum input voltage, per input conditions |
|
|
|
12VDC |
10.4/10.6* |
13.8 |
16.5 |
85 |
87 |
|
|
|
|
|
|
24VDC |
19/21* |
27.6 |
33 |
87 |
89 |
|
*Thermal |
105 C internal temperature. Warning buzzer 5 C before shutoff |
|
|
|
32VDC |
26.5/28* |
36.8 |
44 |
88 |
90 |
|
|
|
|
|
|
48VDC |
41.5/42.5 |
55.2 |
62 |
87 |
89 |
|
Output Short |
Unit shuts off(manual reset) |
|
|
|
66VDC |
57.5/58.5* |
75.9 |
91 |
88 |
90 |
|
*Automatically reset |
|
|
|
|
108VDC |
94/95* |
125 |
149 |
87 |
90 |
|
|
|
|
|
|
*Indicates typical cut-off voltage/warning buzzer voltage |
|
|
|
|
|||||
|
|
¹ +/-3% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GENERAL |
|
ENVIRONMENTAL |
|
|
|||||
|
|
Conditions |
Minimum |
Typical |
Maximum |
|
Temperature |
-25 to 30C full power |
|
|
|
|
|
Waveform |
- |
SINUSOIDAL |
- |
|
|
derated above 30 C |
|
|
|
|
|
Voltage Output |
-5% |
NOMINAL |
+5% |
|
|
|
|
|
|
|
|
Line regulatiion |
- |
0.10% |
0.50% |
|
Humidity |
5 to 95% non condensing |
|
|
|
|
|
Load Regulation |
|
0.50% |
1% |
|
|
|
|
|
|
|
|
Distortion |
- |
| |||||||