JG4003-8: 8V / 75A POWER SUPPLY W/ PFC

 

 

 

 

           Features

                 Μodular Construction

                 Output Voltage 8.0V

                 0.99 Power Factor Correction to EN61000-3-2

                 INPUT: 90 to 264 VAC or 100-300 VDC

                 Agencies (UL, cUL, CE, TUV, NRTL)

                 100-300 VDC input (not agency certified)

                 Paralleled Modules for Increased Output Power

                 All Outputs Isolated and Fully Regulated

                 All outputs floating

                 Output Noise and Ripple as low as 0.25% or

                                  10mV typ. (at any load, 20MHz BW)

                 Low Output Common-Mode Noise

                 Active Load Sharing for N+1 Redundancy

                 Operating Temperature 0° to 75° .C

                 EMI: Mil Std.461D 461E 462

 

           Options

                 VXI/VME Signal Set

                 N+1 Redundancy

                 Output Good and AC Power Fail Signals

                 Global and Individual Output Inhibit

Multiple output  3UP

 

 

 

 

 

 

 

 

ELECTRICAL SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PARAMETER

 

LIMITS

 

CONDITIONS

 

 

Input Operating AC Voltage

 

90-264 VAC (47-63Hz)

 

Agency  recognized

 

 

Input Operating DC Voltage

 

100-350 VDC

 

Not agency recognized

 

 

Total Output Power

 

600 Watts

 

90-264VAC @ 50° C

 

 

Power Factor Correction

 

>0.99 Meets EN 61000-3-2 Class D

 

 

 

 

Conducted EMI

 

EN 55022 Class A compliant                            Mil Std 461D, 461E, 462 compliant

 

 

 

 

Safety / Agencies

 

UL, cUL, CE,TUV, NRTL

 

90-264 VAC only

 

 

Efficiency

 

75% min.

 

115 VAC 700W (output)

 

 

Inrush Current

 

45A Max

 

240 VAC

 

 

Undervoltage Lockout

 

80 VAC typ.

 

 

 

 

Hold-Up Time

 

>20ms

 

90 VAC, 700W (output)

 

 

Power Fail Warning

 

> 8ms

 

90 VAC, 700W (output)

 

 

VME/VXI Signals

 

per VME/VXI specification

 

Optional

 

 

DC Power Good Signal

 

-10% at any output

 

Optional

 

 

Output Over Current Protection

 

+105-125% of full load (automatic recovery)

 

 

 

 

Output Over Voltage Protection

+115-125% of Nominal Output voltage (latching)

 

 

 

 

Output Over Temperature Protection

55°C Ambient (latching)

 

700W (output)

 

 

Output Ripple & Noise

 

0.5% or 20mv pk-pk (whichever is greater)

 

20 MHz BW, any load

 

 

 

 

(0.25% or 10mV pk-pk typ.)

 

 

 

 

Transient Response

 

3% or 150 mV (whichever is greater)

 

25% Step load from 75% to

 

 

 

 

250 μSec Recovery to 1% or 50 mV

 

100% or from 100% to 75%

 

 

Regulation

 

Line 0%

 

90 to 264 VAC

 

 

 

 

Load 0.2% max

 

No Load to Full Load

 

 

 

 

Cross 0%

 

Any Condition

 

 

 

 

Thermal 0.02%/deg. C max.

 

0 to 75°C

 

 

Remote Sense

 

0.5V max Cable Drop Compensation

 

 

 

 

Current Share

 

Avail. on single  output modules

 

 

 

 

Global Output Inhibit

 

Isolated TTL input

 

 

 

 

 

 

 

 

 

 

 

MECHANICAL SPECIFICATIONS

 

 

 

 

 

 

 

 

 

Cooling

 

Internal built-in fans 40CFM Total

 

 

 

 

Environmental

 

Storage Temp. -20 to 85° C

 

 

 

 

 

 

Operating Temp.0 to 75° C

 

 

 

 

 

 

Humidity 5 to 95% non-condensing

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

2.50" X 5.0" X 7.30"

 

 

 

 

 

 

 

 

 

 

 