JG4002-2: 2V / 80A POWER SUPPLY W/ PFC
Features Μodular Construction Output Voltage 2.0V 0.99 Power Factor Correction to EN61000-3-2 INPUT: 90 to 264 VAC or 100-300 VDC Agencies (UL, cUL, CE, TUV, NRTL) 100-300 VDC input (not agency certified) Paralleled Modules for Increased Output Power All Outputs Isolated and Fully Regulated All outputs floating Output Noise and Ripple as low as 0.25% or 10mV typ. (at any load, 20MHz BW) Low Output Common-Mode Noise Active Load Sharing for N+1 Redundancy Operating Temperature 0° to 75° .C EMI: Mil Std.461D 461E 462
Options VXI/VME Signal Set N+1 Redundancy Output Good and AC Power Fail Signals Global and Individual Output Inhibit |

|
Multiple output 2UP |
|
|
|
|
|
|
|
|
|
|
ELECTRICAL SPECIFICATIONS |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PARAMETER |
|
LIMITS |
|
CONDITIONS |
|
|
|
Input Operating AC Voltage |
|
90-264 VAC (47-63Hz) |
|
Agency recognized |
|
|
|
Input Operating DC Voltage |
|
100-350 VDC |
|
Not agency recognized |
|
|
|
Total Output Power |
|
160 Watts |
|
90-264VAC @ 50° C |
|
|
|
Power Factor Correction |
|
>0.99 Meets EN 61000-3-2 Class D |
|
|
|
|
|
Conducted EMI |
|
EN 55022 Class A compliant Mil Std 461D, 461E, 462 compliant |
|
|
|
|
|
Safety / Agencies |
|
UL, cUL,CE,TUV, NRTL |
|
90-264 VAC only |
|
|
|
Efficiency |
|
75% min. |
|
115 VAC 700W (output) |
|
|
|
Inrush Current |
|
45A Max |
|
240 VAC |
|
|
|
Undervoltage Lockout |
|
80 VAC typ. |
|
|
|
|
|
Hold-Up Time |
|
>20ms |
|
90 VAC, 700W (output) |
|
|
|
Power Fail Warning |
|
> 8ms |
|
90 VAC, 700W (output) |
|
|
|
VME/VXI Signals |
|
per VME/VXI specification |
|
Optional |
|
|
|
DC Power Good Signal |
|
-10% at any output |
|
Optional |
|
|
|
Output Over Current Protection |
|
+105-125% of full load (automatic recovery) |
|
|
|
|
|
Output Over Voltage Protection |
+115-125% of Nominal Output voltage (latching) |
|
|
|
|
|
|
Output Over Temperature Protection |
55°C Ambient (latching) |
|
700W (output) |
|
|
|
|
Output Ripple & Noise |
|
0.5% or 20mv pk-pk(whichever is greater) |
|
20 MHz BW, any load |
|
|
|
|
|
(0.25% or 10mV pk-pk typ.) |
|
|
|
|
|
Transient Response |
|
3% or 150 mV (whichever is greater) |
|
25% Step load from 75% to |
|
|
|
|
|
250 μSec Recovery to 1% or 50 mV |
|
100% or from 100% to 75% |
|
|
|
Regulation |
|
Line 0% |
|
90 to 264 VAC |
|
|
|
|
|
Load 0.2% max |
|
No Load to Full Load |
|
|
|
|
|
Cross 0% |
|
Any Condition |
|
|
|
|
|
Thermal 0.02%/deg. C max. |
|
0 to 75°C |
|
|
|
Remote Sense |
|
0.5V max Cable Drop Compensation |
|
|
|
|
|
Current Share |
|
Avail. on single output modules |
|
|
|
|
|
Global Output Inhibit |
|
Isolated TTL input |
|
|
|
|
|
|
|
|
|
|
|
|
|
MECHANICAL SPECIFICATIONS |
|
||||
|
|
|
|
|
|
|
|
|
|
Cooling |
|
Internal built-in fans 40CFM Total |
|
|
|
|
|
Environmental |
|
Storage Temp. -20 to 85° C |
|
|
|
|
|
|
|
Operating Temp.0 to 75° C |
|
|
|
|
|
|
|
Humidity 5 to 95% non-condensing |
|
|
|
|
|
|
|
|
|
|
|
|
|
Dimensions |
|
2.50" X 4.13" X 7.30" |
|
|
|
|
|
|
|
|
|
|
|
|
|
972-699-9976 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||