AC/DC STANDARD & HIGH VOLTAGE POWER SUPPLIES

Jim D. Gray & Associates, Inc.

Supporting O.E.M.ís since 1977

1-972-699-9976

Encapsulated (Potted) Series -
for immunity to shock, vibration, moisture, humidity, dust and insects.

Generic Model

Standard Input Voltage Range: 115/230 +/-15%

No. of outputs

MAXIMUM output parameters - VA can not exceed maximum output power

Package Type

Features

Power (Watts)

Voltage (Volts)

Current (Amps)

PWI 100

95-264VAC or 120-360VDC

1

100

12, 24 48

8

6.1"x3.2"x3"

Adverse environment applications

POL 59

115/230

1

250

12, 24, 48

20

4.25"x7.5"x2.75"

Adverse environment applications

POL 400

115/230VAC or 250-370VDC

1

400

12, 24, 36, 48

33

15.15"x9.13"x3"

Adverse environment applications

 

HVC Series
High Output Voltage Converters

Generic Model

Standard Input Voltage Range: 115/230 +/-15%

No. of outputs

MAXIMUM output parameters - VA can notexceed maximum output power

Package Type

Features

Power (Watts)

Voltage (Volts)

Current (Amps)

HVC 319

115/230VAC

1

500

120, 240

6

F4

High voltage

FHVC 319

115/230VAC

1

700

125, 250

5.6

FF4

High voltage

HVC 2000

115/230VAC

1

2000

85...300

23 max

5.3"x7.5" x15.5"

High voltage

 

Standard AC-DC Power Supplies

Generic Model

Standard Input Voltage Range: 115/230 +/-15%

No. of outputs

MAXIMUM output parameters - VA can not exceed maximum output power

Package Type

Features

Power (Watts)

Voltage (Volts)

Current (Amps)

EOL70

115/230VAC

1

60

12,24,36,48

5

F1

Available as Eurocard
(plug-in module)

EOL76

115/230VAC

3

60

5,+/-12

6

F1

Available as Eurocard
(plug-in module)

SIM98

95-264VAC

4

65

5,+/-12,24

5

6.25"x4.1"x1.5"

Open Frame

HOW 100

95-264VAC

1

100

5...130

20

F0

Medical grade

EOW 70

95-264VAC

1

100

12...130

12

F0

-

MIW 100

95-264VAC

1

100

5...130

8

F0

-

MIW 102

95-264VAC

2

100

130,130

6,6

F0

Universal

LIN 67

115/230VAC

3

100

24,+/-24

10, +/-1

F2

 -

MIW 103

95-264VAC

3

100

12...130

6,1,3,1

F1

Universal

MIW 104

95-264VAC

4

100

+/-5, +/-12

6,1,3,1

F1

Universal

MIW 150

95-264VAC

1

150

130

12

F1

Universal

MIW 152

95-264VAC

2

150

12...130

12,12

F1

Universal

MIW 162

95-264VAC

2

150


+/-12, +/-24, +/-48

6,3,1.5

F1

-

EOL 67

115/230VAC

3

150

5,+/-12

12, +/-3

F2

 -

OPF 84

115/230VAC

5

150

0...24

15,+/-3,-1

F3

 -

EOL 59

115/230VAC

1

180

12...48

20

F1

 -

EOL 90

115/230VAC

1

180

12...48

15

F2

 -

EOL 95

115/230VAC

2

180

+/-24, +/-48

6,6

F2

OLC 53

115/230VAC

1

200

5...125

25

F2

 -

HBC 65

115/230VAC

1

300

120

40

F3

 -

HBC 265

115/230VAC

2

300

120,120

15,15

F3

 -

HBC 465

115/230VAC

4

300

60,24,24,24

20,+/-3,-1

F3

 -

FHBC 65

115/230VAC

1

500

12...125

40

F3

Forced air

HBC 319

115/230VAC

1

500

24...120

20

F4

Convection/conduction cooled

LVC 319

115/230VAC

1

500

12

40

F4

Low DC output

FHBC 319

115/230VAC

1

700

24,† 48

30

F4

Forced air

HBL 1000

115/230VAC

1

1000

24...125

41

2Ux11"x11.5"

Low profile,
Forced air

HBC 1000

115/230VAC

1

1000

24...54

75

UT

Forced air

2HBC 265

115/230VAC

4

1000

ANY

-

17.4"X4.9"X11.5"

-

HBC 1200

115/230VAC

1

1200

24, 48

80

UT

Forced air

HBC 2000

170...265VAC

1

2000

24, 28, 48, 54

70

7.4"x4.9"x11.5"

Forced air

HBC 5000

180...264VAC

1

5000

48, 200, 300

25

4Ux19"x15"

19" rack mount

Note: Most models can be equipped with auto-ranging or switch selection 115/230 as an option.

 

HOME

MANUFACTURERS

CONTACT US

GET A QUOTE